Westinghouse Outdoor Lantern Post 6680800 Manual De Instruções
4
Line art shown may not exactly match the fixture enclosed. However, the installation instructions do apply to this fixture.
FIGURE 2.
FIGURE 3.
POST (C)
POST (B)
*SUPPLY
WIRE
*SUPPLY
WIRE
*FIXTURE FITTER (B)
*FIXTURE FITTER (A)
CONVENIENCE
OUTLET (D)
OUTLET (D)
COVER
PLATE (C)
PLATE (C)
SHEET
METAL
SCREWS (E)
METAL
SCREWS (E)
*NOT SUPPLIED
*NOT SUPPLIED
WHT
WHT
WHT
BLK
BLK
BLK
GND
GND
WHT
WHT
WHT
BLK
RED
GND
GND
BLK
BLK
GND
PHOTO
ELECTRIC
CONTROL (A)
ELECTRIC
CONTROL (A)
PHOTO ELECTRIC CONTROL WIRING (FIGURE 2.)
CAUTION: Do not exceed 1000 watts for photoelectric control.
NOTE: When connecting wires, loop wires below the photocell to avoid water accumulation.
NOTE: When connecting wires, loop wires below the photocell to avoid water accumulation.
1. To connect wires, take white fixture wire from group A in fig. 1 and connect to red
photoelectric control (A from fig. 2) wire by following steps 3, 4, and 5 under wiring
instructions (see fig 1).
2. Repeat steps 3, 4, and 5 under wiring instructions with the black fixture and outlet box
wires (see fig. 1).
3. To connect ground wires, follow steps 4 and 5 from wiring instructions for fixture and
outlet box ground wires.
4. Slide fitter (B from fig. 2) onto post (C from fig. 2) and secure into place.
OUTLET WIRING (FIGURE 3.)
1. To connect wires, take white fixture wire from group A in fig. 1 and connect to red
photoelectric control wire by following steps 3, 4, and 5 under wiring instructions (see fig 1).
2. Repeat steps 3, 4, and 5 under wiring instructions with the black fixture and outlet box wires.
3. To connect ground wires, follow steps 4 and 5 from wiring instructions for fixture and
3. To connect ground wires, follow steps 4 and 5 from wiring instructions for fixture and
outlet box ground wires.
4. Slide fitter (A from fig. 3) onto post (B from fig. 3) and secure into place.
5. Place cover plate (C from fig. 3) on flat area of post (B from fig. 3) over convenience outlet
5. Place cover plate (C from fig. 3) on flat area of post (B from fig. 3) over convenience outlet
(D from fig. 3) and secure into place with sheet metal screws (E from fig. 3).