Wegener Communications 6420 Manual Do Utilizador

Página de 135
 
 
iPump 6420 User’s Manual
 
www.wegener.com 
800070-01 Rev B 
Chapter 1, Page 13 
1.4. 
iPump 6420 Specifications 
Characteristic 
Specification 
 
 
DVB-S1-QPSK Tuner 
RF Input 
Input Impedance 
75 Ω unbalanced 
Input VSWR, 75 Ω system 
< 2:1 (9.0 dB R.L. min), 950-1450 MHz 
< 3:1 (6.0 dB R.L. min), 1450-2150 MHz 
Surge Resistance 
Survives up to 10 direct-coupled 8kV discharges (per IEC 
801-2) 
RF Tuning 
Input Frequency Range 
950 to 2150 MHz 
LO Leakage at Input 
< -50 dBm 
Symbol-rate Range 
2 to 45 Msps (may be limited by Transport Rate Limits) 
Tuning Resolution 
10 kHz 
Input Signal Level Range 
-25 to -65 dBm 
Signal Level Warning 
Limits 
Warns within +10/-5 dB of upper limit and +5/-10 of lower 
limit 
Maximum Aggregate Input 
Power 
-8 dBm min 
Demodulator/FEC 
Modulation QPSK 
(α=.35) per DVB (EN300 421) 
Carrier acquisition range 
+1 MHz or +10% of symbol-rate QPSK, whichever is greater  
Max Eb/No @ Quasi-
error-free threshold (less 
than one uncorrected 
error-event per hour) 
Per EN300 421: 
QPSK R=1/2: 4.5 dB, 
QPSK R=2/3: 5.0 dB, 
QPSK R=3/4: 5.5 dB, 
QPSK R=5/6: 6.0 dB, 
QPSK R=7/8: 6.4 dB, 
Unitless metric SIGNAL corresponds to input power as 
follows: 
 
Above -25dBm:   Extrapolated up to 100+ 
-25dBm:    90     -55dBm:   30 
-35dBm:    70     -65dBm:   10 
-45dBm:    50      no signal <0 
Below -65dBm:    Extrapolated from 10 down to <0 
RF Power Level Estimator 
(locked to carrier or not) 
Accuracy: unit to unit <+5 dB; over frequency <+10 dB 
LNB DC POWER 
(supplied on RF center conductor) 
Activation 
User or network controlled selectable: ON or OFF 
Voltage  
~ +18.7 VDC nominal at no loading, +18.0 VDC min. at max 
loading 
Current (full load) 
350 mA max. 
Short circuit protection 
Thermal fuse, tripping at ~500 mA. 
European “Universal 
LNB” 
Implements LNB polarization & frequency-band control, per 
ASTRA recommendation