Wilson WAM-5500-375/500 Manual Do Utilizador

Página de 12
      10 
SM-165 
SHAFT & CASING REPLACEMENT 
In order to replace the shaft and casing follow these steps: 
1. 
Remove the brush from the Shaft & Casing. 
2. 
Un-screw the shaft from the “Shaft Drive Connector” 
3. 
Reverse the Shaft & Casing until it comes back out from the feed wheel. 
4. 
Remove the “Stop Collar”, “Stop Spring” and the “Spring Cone” from the worn 
Shaft & Casing then replace it onto the new Shaft & Casing. 
5. 
Feed the new Shaft & Casing in to the machine and then screw the back end of the 
shaft & casing on to the “Shaft Drive Connector”  
6. 
Attach the new brush and continue on with  your cleaning cycle. 
•   
Note: Remove the plug from the power outlet before carrying out any  
 
adjustment service or maintenance. 
•   
Safety coupling replacement:  A 80 in-lb Safety Coupling (#9600-0102) is 
 
supplied within the motor connection assembly as standard. This will break if 
 
the shaft is overloaded by forcing cleaning tool within the tube. A hook type 
 
removal tool (#9600-0055) is supplied for removing this broken unit. Engage 
 
the far end of the broken coupling with this tool and pull the coupling out. 
•   
Storage:  To store, disconnect water supply hose and gun assembly.  
 
Disconnect flexible shaft from machine. Dry out the shaft with an air blast 
 
through a hose fitting (optional #9614) attached to large aluminum coupling. 
 
Store the tube cleaner in a dry, heated place. 
•   
Lubrication:  Periodically, grease ball bearing inside motor connector housing 
 
through grease fitting, usually every 200 hours of services. 
•   
Replacement of cords or electrical components:  If supply cord is damaged, it 
 
must be replaced by a special cord or an assembly available from the factory. 
MAINTENANCE 
 
 
   
 
 
    3 
SM-165 
1.  Place the drive unit on its wheels and bumper. 
2.  Take the handle and slide in to the slots. 
3.  Insert the quick-release pins thru the handle as shown below. 
ASSEMBLY 
PIN 
UP 
SHAFT EXIT 
The WILS-MATIC tube cleaner at all times should be operated with the 
covers in place. In addition, it should be operated only with the top side 
(side with shaft exit) up
, as illustrated below:  
OPERATING POSITION