WHP Wireless DL360 Manual Do Utilizador

Página de 246
160 
 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide 
 
Accelerator Status: Possible Data Loss in Cache 
Description: Possible data loss was detected during power-up due to all batteries 
being below sufficient voltage level and no presence of the identification 
signatures on the array accelerator board. 
Action: No way exists to determine if dirty or bad data was in the cache and is 
now lost. 
 
Accelerator Status: Temporarily Disabled 
Description: Array accelerator board has been temporarily disabled. 
Action: Check the Disable Code field. 
 
Accelerator Status: Unrecognized Status 
Description: A status was returned from the array accelerator board that ADU 
does not recognize. 
Action: Obtain the latest version of ADU. 
 
Accelerator Status: Valid Data Found at Reset 
Description: Valid data was found in posted-write memory at reinitialization. 
Data will be flushed to disk. 
Action: No error or data loss condition exists. No action is required. 
 
Accelerator Status: Warranty Alert 
Description: Catastrophic problem exists with array accelerator board. Refer to 
other messages on Diagnostics screen for exact meaning of this message. 
Action: Replace the array accelerator board.