 Troubleshooting 
179 
 
Storage Enclosure on SCSI Bus X Indicated that the Fan is Degraded... 
...SOLUTION: this condition usually occurs on enclosures with multiple fans and one of 
those fans has failed. Replace any fans not operating properly.  
Description: One or more fans in the external storage unit have failed. 
Action: Replace the failed fans. 
 
Storage Enclosure on SCSI Bus X Indicated that the Fan Module is Unplugged... 
...SOLUTION: Make sure the fan module is properly connected. 
Description: A fan in the external storage unit is not connected properly. 
Action: Check and reseat all fan connections securely. 
 
Storage Enclosure on SCSI Bus X - Wide SCSI Transfer Failed... 
...SOLUTION: This may indicate a bad SCSI cable on bus X. Try replacing the cable.  
Description: A cable on bus X has failed. 
Action
1.  Replace the failed cable. 
2.  If the problem persists, contact an authorized service provider. 
 
Swapped Cables or Configuration Error Detected. A Configured Array of Drives... 
...was moved from another controller that supported more drives than this controller 
supports. 
SOLUTION: Upgrade the firmware on this controller. If this doesn’t solve the problem, 
then power down system and move the drives back to the original controller.