WHP Wireless DL360 Manual Do Utilizador

Página de 246
218 
 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide 
 
A CPU Power Module (System Board, Socket X)... 
...A CPU Power Module (Slot X, Socket Y) Failed 
Event Type: Power module failure 
Action: Replace the power module. In the case of an embedded power module, 
replace the system board. 
 
ASR Lockup Detected: Cause 
Event Type: System lockup 
Action: Examine the IML ("Integrated Management Log" on page 
determine the cause of the lockup, and then refer to the HP ROM-Based Setup 
Utility User Guide,
 on the server Documentation CD or at the SmartStart website 
(
information. 
 
Automatic Operating System Shutdown Initiated Due to Fan Failure 
Event Type: Fan failure 
Action: Replace the fan. 
 
Automatic Operating System Shutdown Initiated Due to Overheat Condition... 
...Fatal Exception (Number X, Cause) 
Event Type: Overheating condition 
Action: Check fans. Also, be sure the server is properly ventilated and the room 
temperature is set within the required range. 
 
Blue Screen Trap: Cause [NT]... 
...Kernel Panic: Cause [UNIX] 
Abnormal Program Termination: Cause [NetWare]