INSTALLATION
RIGID PIPE VENTING - VERTICAL TERMINATIONS
for both Residential & Manufactured Homes/Mobile Homes
The shaded areas in the two diagrams below show all allowable combinations of straight vertical and offset to vertical runs with
vertical terminations. Maximum t w o 45
vertical terminations. Maximum t w o 45
o
elbows (not including the 45
o
elbow attached to the unit.). All vertical and offset to vertical
vent installations require Vent Restrictor #1. If the vent is ENCLOSED in a chase (min. size 9" x 9") maintain a 1-1/4" clearance to combustibles.
Offset to Vertical Terminations
Vent Restrictor must be set at 5/8" for this venting installation.
Straight Vertical
Terminations
RIGID PIPE VENTING -
HORIZONTAL TERMINATIONS
The shaded area in the diagram below shows all allowable combinations
of vertical runs with horizontal terminations. Maximum one 90
of vertical runs with horizontal terminations. Maximum one 90
O
elbow
(two 45
o
elbows equal one 90
o
elbow) using Dura-Vent Venting Systems
Residential and Manufactured Homes /
Mobile Homes Installations
The venting arrangements diagrammed below, have a minimum of 75% (flue loss)
efficiency with Fan Off, as required for manufactured homes. (Actual efficiency
may be as high as 85%.)
efficiency with Fan Off, as required for manufactured homes. (Actual efficiency
may be as high as 85%.)