Cellboost BOXER 999-823 Manual Do Utilizador

Página de 88
5-1
Section 5 – Troubleshooting
The following procedures will assist you in determining the potential cause of a machine 
operating problem.
Problem
Possible Causes
Corrective Action
Starter does not turn the 
engine over.
• Trencher control lever is either 
in Forward or Reverse position 
and the operator presence 
control is depressed.
• Move lever to neutral 
position.
• Release operator presence 
control.
• Battery is dead.
• Charge the battery.
• If battery does not hold a 
charge, replace the battery.
• Electrical connections are 
corroded or loose.
• Check electrical connections 
for good contact.
• Remove cables from battery 
terminals and fully clean 
battery terminals and cable 
clamps.
•  If the cable clamps cannot be 
properly cleaned, replace 
connectors.
• Relay or starter switch is 
defective. 
• Contact Authorized Service 
Dealer.
• Engine is in hydraulic lock due 
to a cylinder filled with fuel.
• Allow engine to cool before 
attempting this procedure.
• Remove spark plugs and turn 
engine over to pump excess 
fuel from engine cylinder.
• Make sure to clean up any 
spilled fuel before attempting 
to start the engine.
Engine will not start, 
starts hard, or fails to 
keep running.
• Trencher control lever is not in 
neutral position.
• Move lever to neutral 
position.
• Fuel tank is empty.
• Fill fuel tank with fuel.
• Air cleaner is dirty.
• Clean air filter housing and 
replace the filter elements.
• Spark plug dirty or fouled.
• Replace spark plug.
• Dirty or contaminated fuel filter.
• Replace fuel filter.
• Dirt, water, or stale fuel is in fuel 
system. 
• Drain fuel in tanks into an 
appropriate storage container 
and dispose of bad fuel 
properly.
• Refill fuel tanks with fresh, 
clean fuel.
• Replace fuel filter.
• 15 Amp fuse blown.
• Replace fuse.