Cellboost BOXER 427W Manual Do Utilizador

Página de 86
6-7-06 - Fifth Proof
5-1
Section 5 – Troubleshooting
The following procedures will assist you in determining the potential cause of a machine 
operating problem.
 
Make sure to follow all safety precautions stated in this manual when 
doing any work on the machine.
Problem
Possible Causes
Corrective Action
Starter does not turn the 
engine over. 
• Auxiliary hydraulics lever is 
either in Forward or Reverse 
position with no hydraulically 
powered attachment installed.
• Move lever to neutral 
position.
• Battery is dead.
• Charge the battery.
• If battery does not hold a 
charge, replace the battery.
• Electrical connections are 
corroded or loose.
• Check electrical connections 
for good contact.
• Remove cables from battery 
terminals and fully clean 
battery terminals and cable 
clamps.
• If the cable clamps can not be 
properly cleaned, replace 
connectors.
• Relay or starter switch is 
defective. 
• Contact Authorized Service 
Dealer. 
• Engine is in hydraulic lock due 
to a cylinder filled with fuel.
• Make sure that the spark plug 
cables have been moved 
away from the engine block 
or any other metal surface. A 
spark could ignite the fuel 
causing a fire or explosion.
• Allow engine to cool before 
attempting this procedure.
• Remove spark plugs and turn 
engine over to pump excess 
fuel from engine cylinder. 
IMPORTANT
DANGER