Panel Operation
SP2060 Owner’s Manual
Fore
w
o
rd
Netw
ork Settings
Ref
erences
P
anel Operation
Intr
oduction 
to the SP2060
The Contr
ols 
and Connector
s
28
X-OVER (Crossover)
Setting the Crossover
Input signals can be divided into specified frequency ranges 
to suit speaker response characteristics prior to output.
The number of division is determined to 1-way through 6-
way, depending on the selected component.
1.
Press the [X-OVER] key repeatedly until the X-
Over display appears on the screen.
2.
Press the [SEL] key for the target Output 
channel.
The [SEL] key LED of the selected channel lights up, 
and the corresponding channel name is displayed. 
3.
Press the [NEXT]/[BACK] keys to select a 
parameter to edit. 
4.
Press the [
INC]/[DEC] keys to set the 
parameter value.
Parameter
Range
Function
LEVEL
, –138.00 through 
+10.00dB
Adjusts the level of the 
signal input to the 
Crossover. The same 
Level setting is used 
for the output channels 
of a component.
POLARITY
NORMAL
INVERTED
The output signal 
phase for each 
frequency range is 
inverted.
HPF
Refer to Step 4.
LPF
OUT 1    LPF
FREQ   = 20.0kHz
OUT 3    LPF
FREQ   = 20.0kHz
OUT 3    LPF
TYPE =24AdjustGc
Parameter
Range
Function
HPF
TYPE
Thru
6dB/Oct
12dB/Oct AdjustGc
12dB/Oct Butrwrth
12dB/Oct Bessel
12dB/Oct Linkwitz
18dB/Oct AdjustGc
18dB/Oct Butrwrth
18dB/Oct Bessel
24dB/Oct AdjustGc
24dB/Oct Butrwrth
24dB/Oct Bessel
24dB/Oct Linkwitz
36dB/Oct AdjustGc
36dB/Oct Butrwrth
36dB/Oct Bessel
48dB/Oct AdjustGc
48dB/Oct Butrwrth
48dB/Oct Bessel
48dB/Oct Linkwitz
Selects an 
attenuation 
amount per 
octave, and a 
type of filter.
If you select 
“Thru,” no filter 
will be applied.
FREQ
(Frequency)
20.0Hz–20.0kHz
Specifies the 
cutoff frequency 
of the high pass 
filter.
Gc
–6dB through +6dB
You can set the 
gain for the cutoff 
frequency (Gc) 
when you select 
“AdjustGc 
(Adjustable Gc)” 
for the Type 
parameter.
LPF
TYPE
Thru
6dB/Oct
12dB/Oct AdjustGc
12dB/Oct Butrwrth
12dB/Oct Bessel
12dB/Oct Linkwitz
18dB/Oct AdjustGc
18dB/Oct Butrwrth
18dB/Oct Bessel
24dB/Oct AdjustGc
24dB/Oct Butrwrth
24dB/Oct Bessel
24dB/Oct Linkwitz
36dB/Oct AdjustGc
36dB/Oct Butrwrth
36dB/Oct Bessel
48dB/Oct AdjustGc
48dB/Oct Butrwrth
48dB/Oct Bessel
48dB/Oct Linkwitz
Selects an 
attenuation 
amount per 
octave, and a 
type of filter.
If you select 
“Thru,” no filter 
will be applied.
FREQ
(Frequency)
20.0Hz–20.0kHz
Specifies the 
cutoff frequency 
of the low pass 
filter.
Gc
–6dB through +6dB
You can set the 
gain for the cutoff 
frequency (Gc) 
when you select 
“AdjustGc 
(Adjustable Gc)” 
for the Type 