Yamaha SP2060 V1.2 Manual Do Proprietário

Página de 56
Panel Operation
SP2060 Owner’s Manual
Fore
w
o
rd
Netw
ork Settings
Ref
erences
P
anel Operation
Intr
oduction 
to the SP2060
The Contr
ols 
and Connector
s
38
Initializing the SP2060
Follow the steps below to initialize the internal memory:
You can select one of the following initialization types:
*
Initializing the current scene backup [CURRENT 
BACKUP] 
*
Initializing all user settings (excluding the libraries) to 
the factory settings [WITHOUT LIB.] 
*
Initializing all settings to the factory settings 
[FACTORY SETUP] 
1.
Turn off the power to the SP2060.
2.
Turn on the power to the SP2060 while 
holding down the [BACK/STORE] key.
The Initialization display appears.
3.
Press the [
INC]/[DEC] keys to select a 
type of initialization.
4.
Press the [NEXT] key to move the cursor to 
the 
 icon, then press the [YES] key.
The Initialization operation starts. During initialization, 
the following status message appears:
When initialization is completed, the SP2060 displays 
the following status message, then automatically restarts.
Mute
When Mute is on, the corresponding Input or Output chan-
nel audio is muted.
You can determine the channel Mute status by checking the 
corresponding channel [MUTE] key LED. 
MUTE OFF :  Dark
MUTE ON :  Illuminated
1.
Press the [MUTE] key to select the Mute 
display. 
2.
Press the [SEL] key for the target channel.
The channel audio is muted and the [MUTE] key LED 
lights up. Pressing the channel [SEL] key repeatedly tog-
gles between Mute on and off.
Output port name display
You can view the output port name on the component of 
each OUTPUT channel  in the display.
1.
With [LEVEL], [DELAY], [EQ], [ROUTING], [X-
OVER], or [LIMITER] selected, hold down the 
[SEL] key of the channel you want to view for 
two seconds or longer.
The upper row shows the output port name on the com-
ponent, and the lower row shows the configuration 
name.
When the internal memory is initialized, all data stored in 
the memory will be lost. Use caution when you execute 
this function.
NOTE
To cancel the initialization operation, select “Exit” and confirm 
the cancellation. Alternatively, simply turn off the power to the 
SP2060.
CAUTION
INITIALIZE
FACTORY SETUP    
INITIALIZE
EXECUTING..
INITIALIZE
COMPLETED!
NOTE
You can mute or unmute even if the User Lock function is turned 
on
NOW SELECT KEYS
ACT "MUTE" ->
1
B
A
3way-1  MID
[2x3way       ]