Yamaha XMV4280/XMV4140/XMV4280-D/XMV4140-D Manual Do Proprietário

Página de 42
Controls and Functions
XMV4280/XMV4140/XMV4280-D/XMV4140-D Owner’s Manual
14
Switch 1–3 (UNIT ID) 
(XMV4280/XMV4140 only)
Use the DIP switches 1–3 to specify the upper digit, and 
use the [UNIT ID] rotary switch @2 to specify the lower 
digit to set a maximum of 127 combinations of UNIT ID 
in the range of 01 through 7F (127).
Switch 3 (SECONDARY PORT)
(XMV4280-D/XMV4140-D only)
This sets the Dante [SECONDARY] connector @1 on the 
rear panel as to whether it will be used for daisy chain 
connection or redundant. For details on the connection, 
refer to the “MTX Editor User’s Manual.”
Switch 4 (LED DIMMER)
This specifies the brightness of the front panel indicators 
and display.
Switch 5 (PANEL LOCK)
This specifies the front panel lock setting (locks all panel 
operations including the [MUTE] button o and attenua-
tion adjustments). By selecting the LOCK setting after 
you’ve completed all settings, you can prevent the vol-
ume or mute settings from being inadvertently changed.
Even if the LOCK setting is selected, you can temporarily 
unlock the panel by pressing the [FUNCTION] button !7 
and the [SELECT] A button t. The panel will be re-
locked when one minute has passed without any opera-
tion being performed, or when you once again press the 
[FUNCTION] button and the [SELECT] A button, or 
when you turn off the power.
Switch 6 (IP SETTING)
This selects whether the UNIT ID value will be used as 
the IP address for the unit to communicate with a com-
puter, or whether the IP address will be assigned by the 
editor or the DHCP server.
DIP Switches
Setting
Description
The UNIT ID’s 
upper digit is 
set to 0.
The setting range of the 
[UNIT ID] rotary switch is 
from 01 through 0F.
The UNIT ID’s 
upper digit is 
set to 1.
The setting range of the 
[UNIT ID] rotary switch is 
from 10 through 1F.
The UNIT ID’s 
upper digit is 
set to 2.
The setting range of the 
[UNIT ID] rotary switch is 
from 20 through 2F.
The UNIT ID’s 
upper digit is 
set to 3.
The setting range of the 
[UNIT ID] rotary switch is 
from 30 through 3F.
The UNIT ID’s 
upper digit is 
set to 4.
The setting range of the 
[UNIT ID] rotary switch is 
from 40 through 4F.
The UNIT ID’s 
upper digit is 
set to 5.
The setting range of the 
[UNIT ID] rotary switch is 
from 50 through 5F.
The UNIT ID’s 
upper digit is 
set to 6.
The setting range of the 
[UNIT ID] rotary switch is 
from 60 through 6F.
The UNIT ID’s 
upper digit is 
set to 7.
The setting range of the 
[UNIT ID] rotary switch is 
from 70 through 7F.
DIP Switches
Setting
Description
DAISY CHAIN
The Dante [SECOND-
ARY] connector is used 
for a daisy chain connec-
tion. A signal at the 
Dante [PRIMARY] con-
nector will be transmit-
ted to the next device in 
the chain as is.
REDUNDANT
The Dante [SECOND-
ARY] connector is used 
for a redundant network. 
It will function as backup 
connection, independent 
of the network to which 
the Dante [PRIMARY] 
connector is connected.
DIP Switches
Setting
Description
OFF
Normal brightness.
ON
Reduced brightness. Use 
this setting if the indicators 
and the display are too 
bright.
NOTE
The brightness of the [POWER] indicator !0 will not be 
reduced.
DIP Switches
Setting
Description
UNLOCK
The front panel will not be 
locked.
LOCK
Front panel operations 
other than the power will be 
locked.
DIP Switches
Setting
Description
UNIT ID
The IP address will be 
specified using the UNIT ID 
value.
The IP address will be 
192.168.0.xxx (xxx is the 
UNIT ID value).
However, if the UNIT ID is 
“FF,” xxx is 127.
PC
The IP address will be 
specified by the editor or 
the DHCP server.
NOTE
Set this to the “UNIT ID” position the first time you con-
nect this device to a computer after purchase. After 
specifying the IP address from MTX Editor, change this 