If a problem occurs in the XMV, the [ALERT] indicator will flash and an alert number will appear in the display.
The alert numbers, the corresponding content, and the appropriate actions are listed below.
Alert Numbers and Content
Alert number
Meaning
Response
No display
(only [ALERT] is lit)
The device has not started up correctly.
Turn the power off, then turn on after waiting at least 5 
seconds. If this does not solve the problem, please ini-
tialize the memory. Should this also fails, contact your 
Yamaha dealer.
001.–008.
010.
The internal backup battery has been completely 
exhausted or is not installed.
When you turn off the power, the current settings will be 
lost, and will return to the default values. Please stop use 
immediately, and contact your Yamaha dealer.
011.
The internal backup battery has run extremely low, and 
it is possible that the internal memory has been cleared.
012.
The internal backup battery has only a small amount of 
power remaining.
This does not affect the operation of the device. How-
ever, if you continue using the device, the settings may 
be lost and reset to the default values. Contact your 
Yamaha dealer as soon as possible.
013.
A problem has occurred with the internal clock, and it 
has been initialized (January 1, 2000, 0:00)
If this occurs each time you turn on the power, it is possi-
ble that the internal backup battery has run down or that 
the device has malfunctioned. Contact your Yamaha 
dealer.
If this occurs only once, an abnormality was detected 
with the clock setting and it was initialized; use MTX Edi-
tor to set the time.
015.
The settings saved in internal memory have been lost.
Either the internal backup battery has run low, or the 
device has malfunctioned. Contact your Yamaha dealer.
016.
A memory problem has occurred.
Contact your Yamaha dealer.
021.
The word clock master has become unlocked.
Make sure that the word clock signal is being input cor-
rectly.
022.
The digital signal being input to the [YDIF IN] connector 
is not synchronized to the word clock of this device.
Make sure that YDIF cables are properly connected.
Use cables that meet the required specifications.
023.
The digital signal being input to the [YDIF IN] connector 
is not continuously synchronized to the word clock of 
this device.
030.
There is a problem with the connection of the [YDIF IN] 
connector.
Make sure that YDIF cables are properly connected.
Use cables that meet the required specifications.
040.
Duplicate IP addresses.
Change the IP addresses so that there are no dupli-
cates.
041.
IP address was not set within 60 seconds of startup.
Please check rear panel DIP switch 6 (IP Setting). If DIP 
switch 6 is set to “PC,” use MTX Editor or DHCP server 
to specify the device IP address.
043.
Too many devices are connected to the network.
Reduce the number of devices connected to the net-
work.
050.
The UNIT ID is set to “00.”
Set the UNIT ID to something other than “00.”
051.
Devices with identical UNIT IDs were found connected 
within the same network.
Change the UNIT ID so that there are no duplicates.
100.
The power supply was shut down because d.c. was 
detected on a speaker output.
It is likely that the device has malfunctioned; immediately 
stop using the device and contact your Yamaha dealer.
101.
The power supply was shut down because its tempera-
ture exceeded the allowed limit.
Turn the power off, let the power supply cool down, then 
turn the power on again.
Continuous high-power output will cause high tempera-
tures, so please lower the output level. If the temperature 
is still high, check whether dirt or a foreign object could 
have clogged the cooling fan, and clean the fan if neces-
sary.