Feature Details
Alarm Features
Normal Arm Protection
Status LED: The Control Center Status LED flashes as a visual indicator 
that your vehicle’s security system is active.
Starter Kill: The Failsafe starter kill relay prevents the engine from 
starting 
Note
May require additional parts and installation
Sensor triggers: The shock sensor can distinguish minor impacts from 
major impacts to the vehicle exterior. Minor impacts causes the system 
to emit a Warn-away output by chirping the siren and flashing the 
parking lights for 3 seconds. Major impacts caused for example by a 
forcible entry attempt, results in a Full Trigger output. The siren sounds 
and the lights flash for 30 seconds or longer. Both Warn-away and 
Full Triggers send a message to the remote control. 
Point of entry triggers: Opening the Hood or Trunk causes a Full Trig-
ger output, while opening a Door or turning on the Ignition causes the  
the siren to chirp 3 seconds before beginning the Full Trigger output. 
This 3 second delay allows time to disarm and silence the siren in 
case of accidental trigger. The Full Trigger message is still sent to the 
remote.
Sensor Silent Arm protection
Sensor warn-away and Sensor full trigger activations only send mes-
sages to the remote, while the vehicle’s light flash and siren outputs 
are defeated. Point of entry triggers will activate the light flash, siren, 
and send messages normally.