Venture Products V100A Manual Do Utilizador

Página de 18
P
AGE
 16 
 
What are the security system-call causes ? 
   See security chapter for more explanations. 
Cause 
Exter-
nal 
fuse 
Secu-
rity 
system 
In-
tern
al 
fuse
 
Comment  / solution 
Over-tension (mains 
provider) 
  
Rare.  Change  the  fuse.  Unplug  and 
switch back on. 
DC offset input 
  

Back 
LED: 
on 
  
Generally comes out source elements 
such as CD players. Unplug all cables 
but  AC  mains.  Switch  the  appliance 
back  on.  It  must  operate  perfectly 
alone. In that case, have your faulty 
element fixed/repaired accordingly. 
If the security LED stays on, while the 
amplifier is only connected to AC mains 
(with  input  XLR/RCA  disconnected), 
this indicates an internal failure. Please 
contact your servicing contact point. 
Appliance internal failure  X 
(or) X 
  
The appliance alone does not operate. 
Check  if  heat  dissipaters  are  abnor-
mally hot. 
Contact us 
Shortcut on speakers 
  
  
No  output  sound,  or  very  low  one, 
which can sound bad while the appli-
ance is ON and the display is Normal. 
Check the wiring and components 
Replace the fuse 
Output overload 
  
  
No  output  sound,  or  very  low  one, 
which can sound bad while the appli-
ance is ON and the display is Normal. 
A too loud volume on low-impedance 
speakers can result in such an over-
load. 
Replace the fuse 
Thermal runaway 
  

Front 
LED: 
red 
  
The  amplifier  puts  itself  in  stand-by 
mode (front LED red) if overheating. 
Stop all music, and wait for the ampli-
fier  to  cool  down.  It  will  turn  back  to 
normal  operation  (front  LED  green) 
once the proper heat is reached. You 
can switch it off to quicken the cooling.