Vaillant VRT 392f Guia De Utilização

Página de 36
Operating manual VRT 392f 0020044239_01
14
Screen Title  
screen
Adjustable 
operating values 
(only display = A)
Remarks
Unit
Min. 
value
Max. 
value
Increment/
Selection 
option
Default 
value
 1
Basic data 
Date 
Weekday 
Time of the day 
Select Day, Month and 
Year separately; 
Select Hour and 
Minutes separately
Summer/Winter 
changeover
Auto, Off
Off
 2
HC1 
Time programme
Weekday/Block
Select a weekday or  
a block of days  
(e. g. Mo-Fr)
1 Start/End  Time of 
the day 

3
There are three time 
periods available per 
day or block of days
Hours/
Minutes
10 min
Temperature each 
time period
For each time period, 
an individual room 
temperature can be 
determined
°C
5
30
0,5
20
 4
Hot water time 
programme
Weekday/Block
Select a weekday or  
a block of days  
(e. g. Mo-Fr)
1 Start/End  Time of 
the day 

3
There are three time 
periods available per 
day or block of days
Hours/
Minutes
10 min
 5
Circulation pump 
time programmes
Weekday/Block
Select a weekday or  
a block of days  
(e. g. Mo-Fr)
1 Start/End  Time of 
the day 

3
There are three time 
periods available per 
day or block of days
Hours/
Minutes
10 min
 7
Holiday 
programming for 
the total system
Holiday period 
Start Day, Month, Year 
End Day, Month, Year
Holiday set target 
value heating
Room temperature for 
the holiday time period
°C
5
30
0,5
10
 8
HC1 
parameters
Set-back 
temperature
A set-back temperature 
can be specified for the 
periods between the 
time windows.
°C
5
30
0,5
15
 10
Hot water 
parameters
Hot water target set 
temperature
Target temperature for 
water heating
°C
35
70
1,0
60
 14
Changing the 
name
Heating circuit 1
Any name having up to 
8 characters can be 
entered
Heating 
circuit 1
Hot water
Hot 
water
 15
Release code level
Code number
Access to the level for 
the installer only by 
entering the saved 
code number
1000
Table 4.4 Screens at the operation level for the operator