RATINGS
Boiler Model 
Number
Oil Burner Input
(1)
Heating 
Capacity
MBH
(4)
Net AHRI Ratings
(3)
Min. Natural Draft 
Chimney Size
A.F.U.E. 
Rating
(4)
WITHOUT 
TANKLESS
WITH  TANK-
LESS
G.P.H.
MBH
(2)
Steam 
MBH
Sq. Ft. 
Steam
Round
Square
SFE-3090S
SFE-3090ST
0.90
126
106
80
333
6
8"x8"x15'
82.0
SFE-4125S
SFE-4125ST
1.25
175
147
110
458
6
8"x8"x15'
82.0
SFE-5185S
SFE-5185ST
1.85
259
216
162
675
8
8"x8"x15'
82.0
SFE-6210S
SFE-6210ST
2.10
294
247
185
771
8
8"x8"x15'
82.0
NOTES:
(1)
 Burner input is based on an oil heating value of 140,000 Btu/gal.
(2) 
MBH = 1000 Btu per hour [Btu =British Thermal Unit].
(3) 
Net AHRI Steam Ratings based on piping and pick-up allowance of 1.333. Consult manufacturer before selecting boiler for 
installations having unusual piping and pick-up requirements, such as intermittent system operation, extensive piping, etc.
(4) 
Heating Capacity and AFUE based on 13.0% CO
 with 0.02" 
 
W.C. draft over fire and #1 smoke or less. Tested in accordance with 
U.S. Department of Energy test procedures.
RATINGS, DATA
TANKLESS WATER HEATER CAPACITIES
Boiler Model 
Number
Input 
Rate 
G.P.H.
Tankless 
Heater 
Number
Tankless          
Heater Capacity 
Intermittent Draw 
G.P.M.
Boiler  Water           
Content          
(Gallons)
To Water 
Line
To 
LWCO 
Line
SFE-3090ST
0.90
L-24
2
11
8
SFE-4125ST
1.25
L-24
13
9
SFE-5185ST
1.85
L-24
15
10
SFE-6210ST
2.10
L-24
17
11