QUICK REFERENCE GUIDE  
MICN109/MICN109L 
OPERATIONAL SUMMARY 
AUDIBLE & VISUAL SIGNALS 
 
CONDITION / 
RECOMMENDATION 
 
 
HORN 
POWER 
GREEN LED 
SMOKE 
RED LED 
GAS 
BLUE LED 
CO 
RED LED 
Silent 
On and Blinks 
Off approx. 
every 20 
seconds 
Off 
Off 
Off 
Condition: AC power is present. DC power is 
present. 
Recommendation: None 
Silent 
Off and Blinks 
On approx. 
every 40 
seconds 
Off 
Off 
Off 
Condition: Alarm is powered by battery 
backup. AC power is not present. 
Recommendation: Check the breaker or 
fuse box for power. If the breaker or fuse box 
looks normal, call a licensed electrician for 
assistance. 
3 beeps, 
2 second pause, 
3 beeps, 
6 second pause, 
4 beeps, 
5 second pause, 
1 beep 
Turns off when 
the 3 beeps 
start 
Blinks on 
during the 
cycle of 3 
beeps and 
turns off 
Blinks On in 
sync with the 1 
beep 
Blinks On in 
sync with the 
cycle of 4 
beeps and 
turns off 
Condition: The Test/Silence button has been 
pressed. The test sequence lasts for approx. 
20 seconds. 
Recommendation: None 
Horn does not 
sound when other 
alarms are active or 
when 
interconnected 
alarm
’s test/reset 
button is pressed 
*See below 
Off 
Off 
Off 
Condition:  One  or  more  alarms  not 
responding to interconnected alarm. 
Recommendation:  Press  and  hold  the 
smoke alarm Test/Silence button for at least 5 
seconds. If still no alarm, turn off AC power at 
the circuit breaker or fuse box and disconnect 
the  alarm  from  the  mounting  bracket  and 
make  sure  the  connector  plug  is  securely 
attached on units that did not alarm. If still no 
alarm,  have  a  licensed  electrician  make  sure 
the  yellow  wire  is  not  mistakenly  or 
accidentally  connected  to  the  white  (neutral) 
wire. 
3 beeps, 
2 second pause, 
repeat 
Turns off when 
the 3 beeps 
start 
Blinks On 
approx. once 
every second 
 
Off 
Off 
Condition: Originating Smoke Alarm. 
Recommendation: If hazard is identified, 
take all precautions if an alarm sounds by 
calling an Emergency Service and getting out 
of the home. 
3 beeps, 
2 second pause, 
repeat 
Turns off when 
the 3 beeps 
start 
Off 
Off 
Off 
Condition: Non-originating Smoke Alarm. 
Recommendation: Another interconnected 
smoke alarm has sensed smoke, causing all 
interconnected units to sound. If hazard is 
identified, take all precautions if an alarm 
sounds by calling an Emergency Service and 
getting out of the home. 
4 beeps, 
5 second pause, 
repeat 
Turns off when 
the 4 beeps 
start 
Off 
Off 
Blinks On in 
sync with 4 
beeps 
Condition: Originating CO Alarm. 
Recommendation: If hazard is identified, 
take all precautions if an alarm sounds by 
calling an Emergency Service and getting out 
of the home. 
4 beeps, 
5 second pause, 
repeat 
Turns off when 
the 4 beeps 
start 
Off 
Off 
Off 
Condition: Non-originating CO Alarm. 
Recommendation: An interconnected CO 
alarm has sensed CO, causing all 
interconnected units to sound. If hazard is 
identified, take all precautions if an alarm 
sounds by calling an Emergency Service and 
getting out of the home. 
1 beep, 
2 second pause, 
repeat 
Turns off when 
the 1 beep 
starts 
Off 
Blinks On in 
sync with the 1 
beep 
Off 
Condition: Originating GAS Alarm. 
Recommendation: If hazard is identified, 
take all precautions if an alarm sounds by 
calling an Emergency Service and getting out 
of the home.