41 
 
 
Table 5.  Remote Programming Mode Commands - Continued 
OP 
CODE 
(HEX) 
MNEMONIC/DESCRIPTION 
COMMAND/ACKNOWLEDGEMENT 
A3 
COMMP 
 
Communications setup for 
selecting ports, baud rate, word 
length, stop bits, parity, and method 
of handshaking. 
COMMAND: A3Pbbbbbwsph<CR> 
 
A3 
= Op Code 
= destination port for load 
bbbbb  = baud rate 
= word length 7 or 8 bits 
= number of stop bits 1 or 2 
= parity odd, even, or none 
= handshaking 
<CR>  = terminate command (0D hex)   
 
Port: 
 
0 = main; 1 = AUX 
Baud rate: 
 
00300, 00600, 01200, 
 
02400, 04800, 09600, 
 
19200, 38400, 57600 
Word length: 
 
7 or 8 
Stop bits: 
 
1 or 2 
Parity: 
 
O = odd, E = even, N = none 
Handshaking: 
 
H = CTS/RTS, S = XON/XOFF, 
 
B = both, N = none 
 
ACKNOWLEDGEMENT:  NONE 
 
A4 
NOTES 
 
Used to enter up to 40 characters 
of notes into RAM.  Useful for 
recording keyboard version and 
date, etc. 
COMMAND: A4xxxx-xxxx<CR> 
 
A4 
= Op Code 
xx 
= Note (max of 40 Characters) 
<CR>  = terminate command (0D hex)   
 