Functional description 17
6.2. Controller
The control system is mounted on the separator lid.
The setting for the conveying time and the line clear time are made via the keys (A1: “change-
over” key,  A2: “arrow key”) on the front of the control system. The values which have been set
will be displayed on the display (B). The values which have been set are maintained after the
machine has been shut off.
3 LEDs indicate the respective modes of operation: cleaning (C), conveying (D), line clearing (E).
&
 
The conveying time can be set from 1 to 99 seconds.
The line clear time can be set from 0 to 99 seconds.
The clearing time consists of 2 seconds.
The emptying time consists of 8 seconds.
When the unit is switched on all LEDs blink and the software
version is displayed.