SonicOS 5.8.1.2 Release Notes for the NSA 220/250M Series Appliances 
P/N 232-000648-00 Rev A        
 
 
High Availability 
Symptom 
Condition / Workaround 
Issue 
With Active/Passive High Availability enabled 
with probing, and the primary WAN interface 
configured with a redundant port, the primary 
WAN interface and all routes to this subnet are 
marked as down when the primary port stops 
working. 
Occurs when HA is enabled with probing and the 
primary WAN interface is configured with a 
redundant port. If the link for the active port goes 
down, Load Balancing (enabled by default) will 
change the status of the primary WAN interface to 
“Failover”. All routes to the primary WAN subnet 
will be marked as down and traffic destined to the 
subnet will fail. However, traffic will still succeed to 
any destination that is on the far side of the 
default gateway of the primary WAN interface, by 
using the redundant port. Workaround: Disable 
Load Balancing or HA probing. 
97883 
Module 
Symptom 
Condition / Workaround 
Issue 
The LAN Bypass module’s Bypass Status LED 
indicates that bypass mode is active during the 
boot process, then changes to the normal mode 
in which bypass is ready, but not active.  
Occurs when configuring an SFP module in Layer 
2 Bridge Mode, then replacing it with a LAN 
Bypass module. 
108416 
The ADSL card cannot connect in DHCP mode. 
Occurs when configuring an ADSL card with the 
WAN in DHCP mode. The Status mode, Point-to-
Point Tunneling Protocol (PPTP), and Layer 2 
Tunneling Protocol (L2TP) do not work with this 
configuration. 
106473 
Networking 
Symptom 
Condition / Workaround 
Issue 
On the X1 interface, 1Gbps traffic sometimes 
does not reach the WAN. After configuring the 
link speed, the link status displays the 
previously configured speed. 
Occurs when passing traffic through the X1 
interface with a 1Gbps switch and forcing the X1 
interface’s link speed to 1000Mbps or 100Mbps. 
Workaround: Configure the SonicOS to  
auto-negotiate link speed. 
105890 
Configuring more than one remote appliance 
with a tunnel interface and OSPF could result in 
dropped routes. 
Occurs when an additional remote appliance is 
configured with a tunnel interface and OSPF is 
enabled. 
102961