Indoor Scoreboards
Your scoreboard will require a 120 VAC, 60 Hz, grounded receptacle located within 5 feet of the top-cen-
tre of the scoreboard. Optional 230VAC, 60Hz, is also available. Typically the outlet will be a dedicated 
15 Amp circuit. Refer to the model specific information provided in this package for the exact current load 
for your scoreboard. FIGURE 1 illustrates a generic installation including a controller. Seek the service of 
a qualified electrician to ensure the electrical installation meets all local electrical codes. CDS assumes no 
responsibilities for installations done by others. 
NOTE: On scoreboards with the cULus mark, the scoreboard does not come equipped with a power 
cord as these units must be permanently wired in.
Data cabling for the scoreboard is available in standard lengths (connectors factory installed), or as a kit 
for custom lengths (connectors installed on site). See the DATA CABLING section for more information.
Wall mounting is the preferred method of installation. When determining the installation location, ensure 
-
shipping. Remove and re-install the brackets so that the mounting holes are exposed past the edge of the 
scoreboard. Lifting eyebolts are provided on the top of the scoreboard to facilitate lifting of the unit to its 
type of fasteners selected should be suitable for the type of wall construction and have sufficient capacity 
to support the scoreboard. CDS recommends using 3/8” fasteners. Detailed information regarding mount-
ing locations and fasteners recommendations for your scoreboard model is provided in the documentation 
attached.