Port Monitor Commands 
C340 (u)  Remote monitors off   
 
Turns off remote monitor for the command source, with exception 
given above for remote monitor on. If the local port is in remmonl 
mode, then all remmonl ports in the group will have remmon cleared. 
If it is in remmon mode, remmon will be turned off for only that port.  
 
C341 (u)  Remote monitors on 
 
 
Turns on remote monitor for the command source port, if that is a local 
(repeater). Otherwise, turn remote monitor on for the lowest 
numbered logical port local in the group of which the source port is a 
member. If the command comes from the serial port, set remote 
monitor on for the lowest numbered local logical port in group 0. 
 
C342 (u)  Remote monitor on with local link enabled   
 
Turns on remote monitor for all of the currently linked local (repeater) 
ports in the same group as the command source.  The local repeater 
ports remain fully linked to each other. 
 
C344 (u)  Remote monitor off, port specified   
 
Turns off remote monitor as if the command came from the specified 
port. Syntax is *C344n, where n is the logical port number 
 
C345 (u)  Remote monitor on, port specified   
 
Turns on remote monitor as if the command came from the specified 
port.  Syntax is *C345n, where n is the logical port number. 
 
C346 (u)  Remote monitor on with local link enabled, port specified  
 
Turns on remote monitor with local link enabled as if the command 
source came from the specified port.  Syntax is *C346n, where n is the 
logical port number.