Schlage CO-100 Manual Do Utilizador

Página de 12
9
CO-100 Offl ine Lock User Guide
 BATTERIES 
Installing or Replacing Batteries
1. Remove the battery cover.
2. Remove the Battery Bracket.
3. Install the new batteries. Observe polarity. (Install only new AA Alkaline batteries.)
4. Install the Battery Bracket.
5. Connect the batteries.
6. Reinstall the battery cover.
CAUTION!  Danger of explosion if batteries are incorrectly replaced! Replace only with 
new AA alkaline batteries. Dispose of used batteries according to the manufacturer’s 
instructions.
CY, MS, & MD
993
!
Plug MUST Be on Right
   
Low Battery Indications
 
Changing batteries does not affect any programmed data.
Condition
Indicator
Solution
Batteries Low
After credential PIN is pressed, 9 red 
blinks of Schlage button, then normal 
indicator.
Replace batteries immediately to 
avoid battery failure. Lock is intended 
to operate for 500 cycles in low 
battery condition.
Battery Failure
No LED or beeps
Valid credentials do not grant access
Replace batteries immediately.
Mechanical override key must be 
used to unlock lock.
Battery Failure Mode
In the event of battery failure, the lock will fail As-Is (lock remains in current state, locked or unlocked, 