Ricoh RV5VH Manual Do Utilizador

Página de 52
37
RV5VH3
××
Voltage Detector
Symbol
Item
Conditions
MIN.
TYP.
MAX.
Unit
V
DET
Detector Threshold
2.633
2.700
2.767
V
V
HYS
Detector Threshold Hysteresis
0.081
0.135
0.189
V
I
SS3
Supply Current3*
1
1.2
µA
V
IN
max
Maximum Input Voltage
10
V
V
OPT
min
Minimum Operating Voltage
Specified as the V
DD
1.8
V
Voltage for Device Operation
I
OUT
Output Current
V
DS
=0.5V, V
DD
=1.5V
1.0
2.0
mA
V
DS
=0.5V, V
DD
=3.0V
4.0
5.0
mA
t
PLH
Output Delay
100
µs
V
OUT1
Detector Threshold Temp.Co
–40˚C
Topt
85˚C
±100
ppm/˚C
Topt
I
DOUTleak
D
OUT 
Leakage Current
0.03
0.5
µA
*
) V
DD
=3.0V : unless otherwise specified.
*
1 ) This value only shows the supply current of voltage detector.
V
DD
=3.0V, Topt=25˚C