Chapter 8: Expansion Modules
Enabling The SE 1223HP Scanner
Fit the scanner module over the back of the WORKABOUT PRO
it 
replaces the back plate of the unit.
Fasten the module in place with the screws provided. Tighten the screws to 
a torque of 3 lbs-in (3kgf-cm).
Slide the SW1401 power switch to the right to turn power back on, and 
replace the end-cap, backplate and battery. Tighten the end-cap screws to a 
torque of 3 lbs-in (3kgf-cm).
Figure 8.10 Scanner Module Installed In WORKABOUT PRO
8.1.6.1
Enabling The SE 1223HP Scanner
Simultaneously, press and hold down the <BLUE> <ENTER> and left 
<SCAN> keys for a minimum of 6 seconds. A 
Command>
 prompt is 
displayed on the WORKABOUT PRO screen.
Type s to display the 
Scanner>
 prompt. A list of supported scanners is 
displayed.
Type 2 and press <ENTER> to activate scanner type SE 1223HP.
At the 
Command>
 prompt, type 1 (one) to reboot the unit to 
Windows Mobile 2003 SE.
8.1.7  Installing An SE 923HP Scanner
Warning:
Anti-static devices MUST BE USED during the installation of 
this scanner module. If unavailable, discharge static from your 
body by touching a grounded metallic object before opening any 
covers on the unit.