Polycom Welding System 3725-77601-001H Manual Do Utilizador

Página de 560
Polycom CMA System Operations Guide 
248
Polycom, Inc.
 
MCU Resources—Polycom RMX Platform
Field
Description
Max Total Conferences
Maximum number of total conferences allowed at 
once on this MCU.
Max CP Conferences 
Maximum number of continuous presence (CP) 
conferences allowed, based on the number of 
licenses available. 
Max Video Ports
Maximum number of video ports on which 
participants can be connected.
Max Total Participants
Maximum number of total video participants 
allowed at once on this MCU.
Use Entry Queue
Indicates whether the RMX device supports an 
IVR. 
Entry Queue Number ID
The number that conference participants dial to 
access the IVR prompt to join a conference.
Entry Queue ISDN Number
The number that conference participants dial to 
access the IVR prompt to join a conference.
Audio & Video Settings: The following parameters must be set manually to 
synchronize with the RMX device. See the RMX documentation for more 
information about these settings.
Max Voice Ports
Set this to the maximum number of audio ports 
configured on the RMX device.
Refer to the RMX 2000/4000 Administrator’s Guide 
for more information about this field.
Note
Up to 10 blocks of RMX video ports can be 
converted to 50 audio-only ports, up to a maximum 
of 200 audio-only ports. 
Max CP Resolution
Set this to the highest available video format. 
Choices are: HD1080, CIF, SD15, SD30, and 
HD720.
Refer to the RMX 2000/4000 Administrator’s Guide 
for more information about this field.
Max Bandwidth Capacity 
(Kbps)
The maximum bandwidth to the Polycom RMX 
system.