Configure Alert Thresholds
The CMA system provides administrators with the ability to configure some 
alert thresholds settings. 
To configure alert thresholds
1
Go to Admin > Alert Settings > CMA Alert Threshold Settings.
2
Configure these thresholds:
Encryption Type
For SNMPv3, specifies the privacy protocol for the 
connection between the CMA system and the 
notification receiver. 
The CMA system implements communication with 
authentication and privacy (the authPriv security 
level as defined in the USM MIB). 
Possible values for privacy protocol are:
DES 
AES
Encryption Password
For SNMPv3, specifies the password to be 
associated with the privacy protocol.
Setting
Description
Threshold
Description
Used disk space alert 
threshold
Whenever the system disk space usage in a 
partition (as identified in the CMA Info Dashboard 
pane) exceeds this threshold, the system sends an 
alert and an SNMP trap.
Valid values for this threshold are between 1-100%. 
By default, this threshold is set to 90%.
A threshold setting of 75% or greater is 
recommended and no greater than 95%.
Memory usage alert 
threshold
Whenever the system memory usage (as identified 
in the CMA Info Dashboard pane) exceeds this 
threshold, the system send an alert and an SNMP 
trap.
Valid values for this threshold are between 1-100%. 
By default, this thresh-%old is set to 95%.
A threshold setting between 80-95% is 