3.4.3  SERIAL LINK (RS232 / RS422) 
The current version of PC connector plate, which is fitted on the rear right hand side of the 
Commander Matrix frame, provides either RS232 or RS422 connection capability. The 
factory default setting is RS232: this may be changed by removing the 4 fixing screws, 
withdrawing the rear connector assembly and moving the PCB mounted jumper links to the 
alternate position. Most computers are fitted with D9 fixed sockets for the serial COM port. 
For older models equipped with a D25, suitable adaptors may be easily obtained. 
 
RS232 configuration. 
Commander Sub D9 
Fixed Socket - Pin 
Function 
PC COM Port 
D9 Fixed Socket 
1 DCD 
2 TX 
3 RX 
4 DTR 
0V or GND 
6 DSR 
7 CTS 
8 RTS 
9 n/c 
Case  
 
 
Note: Pin 1 through to Pin 8 MUST be wired 1:1. CAT 5 cable is suitable for most 
applications. 
 
RS422 configuration. 
Commander Sub D9 
Fixed Socket Pin (+,-) 
 
Function 
 
Notes 
4,8 
422 in, +,- 
Pair 1 (RX) 
6,1 
422 out, +,- 
Pair 2 (TX) 
7,2 
422 RTS +,- 
Pair 3 
5,9 
422 CTS +,- 
Pair 4 
3  
Chassis 
 
Connection to external equipment will depend on the manufacturer and model of RS422 
card fitted. The table above only relates to the matrix. 
 
3.4.4  ALARMS 
These are provided on a 9 way D type fixed socket on the rear of the matrix. The function of 
the output is software controlled from the 500-08-10 Changeover card. The output is a 
normally made, solid state relay contact. Maximum current rating is 120mA. 
Commander 
D9 Fixed Socket - Pin 
 
Function 
 
Notes 
1,6 
Right side OK 
Pair 1 
2,7 
Left side OK 
Pair 2 
4,8 
C/O Card OK 
Pair 3 
5,9 
Left side selected 
Pair 4 
3  
Chassis