5.9  500-31-60 STANDARD FACILITY 16 KEY CONTROL PANEL 
The 500-31-60 panel provides 16 programmable lever keys in a 2U rack mount chassis. For 
information on programming the software driven “cut switch” operation, see section 10.3. 
 
5.9.1  SPECIFICATION 
 
Dimensions 
485mm wide x 88.9mm high x 80mm deep 
(approx. including PSU and mating connectors).  
19” x 2RU rack mounting 
Mains Input 
90 – 250 V ac, 50-60Hz 
Current Consumption 
150mA @ 90V, 50mA @ 250V 
 
5.9.2  REAR PANEL LAYOUT 
 
Connector types: 
Matrix 
RJ 45 socket 
GPIO 
D9 Fixed Socket 
Audio I/O 
D15 Fixed Socket 
Footswitch 
D9 Fixed Socket 
 
Matrix – RJ-45 fixed socket on panel 
RJ-45 
Pin 
Function 
 
Panel Data out + 
Pair 
Panel Data out - 
Panel Data In + 
Pair 
Panel Data In - 
Panel Audio out + 
Pair 
Panel Audio out - 
Panel Audio in + 
Pair 
Panel Audio in - 
 Cable 
Screen  
 
 
Headset - 5 Pin XLR Fixed Socket (front 
panel) 
Pin 
Function 
Mic IN (Screen) 
2 Mic 
IN 
3  
Headset Gnd 
4 Headset 
Out 
5 Headset 
Out 
 
Foot Switch - D9 Fixed Socket 
Pin 
Function 
Foot Switch Input 
2 No 
Connection 
3 Chassis 
Ground 
Reserved 
Reserved
 
6 Ground 
Reserved
Reserved
 
Reserved