Trilogy Touch Technology Trilogy Commander Digital Intercom 9 Manual Do Utilizador

Página de 81
Commander Installation Guide 
 
 
 
 
 
 
 
 
 
 
 
Trilogy Communications Limited 
Page 61 of 81 
Issue 9 
 
8.  L
EGACY 
H
ARDWARE
 
The following hardware is no longer supplied by Trilogy Communications. 
8.1  MATRIX CARDS 
•  500-06-00 is marked 5510 on the card ejector since the base card is manufactured by 
Pro-Bel. It carries a Trilogy designed sub board. 
•  500-06-01 replaced the 500-06-00 and is a single board Trilogy design. 
8.1.1  GAIN SETTING ON 500-06-00 
Ports intended for use with cameras will have the appropriate rear connector back fitted in 
the correct position, as per your requirements. The camera RCU has a passive-mixing pad 
fitted, which necessarily inserts a 25dB loss into the 6
th
 port of the associated matrix card. 
The 500-06-00 6 port interface module has a sub-module fitted on which are the analogue 
input and output buffers. The drawing below shows the layout of the 500-06-00 module, with 
its sub-module.  
Note that the 500-06-00 module is based on a Pro-Bel module numbered 5510. The card 
ejector is marked with the number 5510, not 500-06-00. 
On the sub-module are two links, which must be set correctly to provide gain compensation 
for the loss of the mixing pad. Two positions are provided - “NORM” and “CAMS”. One link 
must be moved to the CAMS position; the second link should be removed for operation with 
cameras.