8.5.4  500-40-0X SERIES EXPANSION PANELS 
Control Panels may be linked together to provide additional facilities at one operating 
position. Additional level controls (RENs) or switches may be added. Alternatively, two 
standard panels from the 500-30 series may be linked together and will only utilise a single 
matrix port.  
The following detail refers to expansion panel types: 
•  500-40-00  
8 way encoder panel 
•  500-40-01  
12 way encoder panel 
•  500-40-02  
15 key switch panel 
•  500-40-04  
32 way encoder panel 
An installation specification is given below. 
Dimensions 
485mm wide x 44.5mm high x 100mm deep 
(excluding connectors) 150mm deep (maximum 
including mating connectors) 
19” x 1RU rack mounting 
Mains Input 
90 – 260 V ac, 50-60Hz 
Current Consumption 
150mA @ 90V ac, 50mA @ 250V ac. 
 
 
8.5.4.1  Connector Pin Out 
 
Expansion In - D9 Fixed Socket 
Pin 
Function 
1 Analyse 
Input 
Enable Remote Boot 
3 Ground 
Transputer Link Out + 
Transputer Link In + 
6 Error 
signal 
Out 
7 Reset 
In 
Transputer Link Out- 
Transputer Link In- 
 
Test Port– D9 Fixed Socket 
Pin 
Function 
1 Analyse 
Input 
Enable Remote Boot 
3 Ground 
Transputer Link Out + 
Transputer Link In + 
6 Error 
signal 
in 
7 Reset 
Out 
Transputer Link Out- 
Transputer Link In- 
 
 
Expansion Out– D9 Fixed Socket 
Pin 
Function 
1 Analyse 
Input 
Enable Remote Boot 
3 Ground 
Transputer Link Out + 
Transputer Link In + 
6 Error 
signal 
in 
7 Reset 
Out 
Transputer Link Out- 
Transputer Link In-