Telit Wireless Solutions GE863-QUAD Manual Do Utilizador

Página de 79
 
 
 
 
 
GE863-QUAD 
GE863-PY 
 
 1vv0300715 Rev. 1 - 19/09/06  
  
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Right reserved 
 
page 76 of 79 
 
13.2.8 Moisture 
Sensibility 
The level of moisture sensibility of 
Telit GE863-QUAD / PY modules
 is “3”, according with standard 
IPC/JEDEC J-STD-020, take care of all the relative requirements for using this kind of components. 
 
Moreover, the customer has to take care of the following conditions: 
 
a) The shelf life of GE863 inside of the dry bag shall be 12 month from the bag seal date, when stored 
in a non-condensing atmospheric environment of <40°C / 90% RH 
 
b) Environmental condition during the production: ≤ 30°C / 60% RH according to IPC/JEDEC J-STD-
033A paragraph 5 
 
c) The maximum time between the opening of the sealed bag and the reflow process shall be 168 
hours if the condition b) “IPC/JEDEC J-STD-033A paragraph 5.2” is respected 
 
d) A baking is required if conditions b) or c) are not respected 
 
e) A baking is required if the humidity indicator inside the bag indicates 10% RH or more