OSBURN HYBRID-45 MF FREESTANDING PELLET STOVE 
 
Width: 27”  
Height: 30 1/2” 
Depth: 24 5” 
Weight: 230 lbs. 
Flue size: 3” or 4” 
Hopper Capacity: Up to 70 lbs. 
(This can vary widely depending on pellet size, length, and diameter) 
EPA status: exempt 
Burn rate: 1 lb. to 5.5 lbs. per hour 
BTU range: 8,200 to 45,000 
Electrical consumption:  3.5 Amps lighting cycle 
                                       2.5 Amps. continuous duty 
Control board fuses:  Main: 7.5A-250V fastblow 
                                   Igniter: 5A-250V fastblow 
Electrical requirement: 120VAC 15A 
Approved installations: mobile home, conventional 
 
PREPARATION 
 
Factory packaging must be removed, and some minor assembly work is required 
prior to installation: 
 
• 
The door overlay must be installed on the door frame; 
• 
The louver kit must be installed in front of the heat exchanger. 
 
NOTE: Normally, your dealer will perform these functions. 
 
CLEARANCES 
 
The Osburn Hybrid-45 MF has been tested and listed for installation in residential, 
mobile home.(refer figure 1 & 2) 
FLOOR PROTECTION:  minimum 6” in the front and 6” on each side. The stove 
must be placed on a continuous (grouted joints) noncombustible material such as 
ceramic tile, cement board, brick, 3/8” millboard or equivalent, or other approved or 
listed material suited for floor protection. NOTE: ceramic tile, or any tile, requires a 
continuous sheet beneath to prevent the possibility of embers falling through to the 
combustible floor if cracks or separation should occur in the finished surface, this 
would include floor protection for Built-in raised hearths. Check local codes for 
approved alternatives. 
Clearances are measured from the sides, back and face (door opening) or stove 
body (refer to fig. 3).  
DO NOT USE MAKESHIFT MATERIALS OR COMPROMISES IN THE 
INSTALLATION OF THIS UNIT. 
INSTALL VENT WITH CLEARANCES SPECIFIED BY THE VENT 
MANUFACTURER. 
 
3"
2" *
6"
SIDE
 W
A
L
L
BACK WALL
 
 
 
 
 
 
2"
3"
3"
2"
ADJACENT WALL
AD
JA
CENT
 W
A
LL
 
 
 
 
 
 
 
 
6"
6"
6"
 
 
 
 
 
 
 
 
INSTALLATION
5
FIGURE 1 
Back wall installation
FIGURE 2 
Corner installation
FIGURE 3 