Page 4 - 10
Installation
 © GBC Films Group January 2001
Orbit™ 2000 Operation and Maintenance  Manual
– The voltage measured between the terminal PE and the test points may not exceed
U =3.3V
for
S= 1.0 square millimeters
U = 2.6V
for
S= 1.5 sq. millimeters
U = 1.9V
for
S = 2.5 sq. millimeters
( U ) is the largest drop in voltage and ( S ) is the smallest effective diameter
of the protective conductor in the tested branch of the protective circuit.
c/
Voltage checks
–  from fused disconnect - 240 VAC +/- 10% 3 phase with ground.
– Check each leg, A,B nad C, to ground for proper voltage drop.
– Check main line voltage to locking plug connection on the Orbit™2000.
– Connect plug from Orbit™2000 to electrical supply.
d/
Perform a safety check of all emergency stops, safety latches and lockouts.
– Emergency stop buttons
– Safety shields
– Power on/ off lockout
– Table limit switches
– Feeder head protect  from pile-up table
e/
Power-up the Orbit™2000 and confirm that the temperature contoller is illuminated.
If the temperature controller is not illuminated, check the E-Stops, safety latches or lockouts
for activation.
f/
Check all roatations of motors: Feeder Pile-up, Feeder pile-down, main drive and
compressor/ feeder