Script Command Definitions 
The scripting commands available for use with the Daypart Scheduler are listed in bold lettering (e.g., 
parts
). Their definitions (e.g., Displays the current daypart table) and usage examples are also listed. The 
commands have been divided by general functions (Dayparts, Presets, System parameters, etc.). In use, a 
command is typed in and then the enter or return key is pressed. If the command is executable (e.g., parts), 
then the command is run (e.g., a table of the dayparts is displayed), otherwise the cursor simply moves to 
the next entry line. 
 
Dayparts 
parts 
   Displays 
the 
current 
daypart 
table 
partadd <day> <time> 
 
Adds a daypart to the daypart table.   
The “day” parameter can be assigned the following days: Sun, Mon, Tue, Wed, Thu, Fri, Sat, M-F, S-S, 
All. The “time” parameter must be defined using the following format: <hour>:<min>:<sec><am | pm> . 
As an example, typing Partadd Mon 5:00:00am <enter> commands the Omnia-6 to add a daypart on 
Monday at 5:00:00am. 
partremove 
 
 
Removes a daypart from the current daypart list. 
Example: partremove Mon 5:00:00am <enter> 
partload   
 
 
Loads a daypart from the PC Card. 
partsave   
 
 
Saves the current daypart to the PC Card. 
 
Presets 
Note: After a preset is saved to the system, the Omnia knows them by their Index Number, not by their 
Preset Name. Therefore, when selecting a preset, you use its index number. When saving presets, you use 
its name! 
 
presets 
    Lists all the currently available factory and user presets by  
     index 
#. 
 
preset <preset index #> 
 
Selects the preset by index # from the list of available presets  
Example: preset 21 <enter> 
 
commands the Omnia-6 to load preset number 21 in the index  
 
 
 
 
 
list. 
 
delete <preset index #>  
 
Deletes a preset from the preset index list by its index number. 
Example: delete 21 <enter> 
 
commands the Omnia-6 to remove preset number 21 from the  
     index 
list. 
rename <preset index #><name> 
Renames the preset by its index number.