Omnia Industries Turntable 6FM Manual Do Utilizador

Página de 131
 
Omnia 6 Use and Installation Guide – Version 1.00a
 
96
96
for both options. 
Initiating Trigger Scripts via the Interface Connector 
As we mentioned, trigger scripts give the user the ability to tie a series of commands to a simple high/low 
logic change occurring on a pin of the 9-pin D-sub Interface connector on the unit’s rear panel. The pins on 
the Interface connector are assigned as follows: 
 
 
 
PIN 1 - activates Trigger Script 1 
 
 
 
PIN 2 - activates Trigger Script 3 
 
 
 
PIN 3 - activates Trigger Script 8 
 
 
 
PIN 4 - activates Trigger Script 6 
 
 
 
PIN 5 - is connected to ground 
 
 
 
PIN 6 - activates Trigger Script 2 
 
 
 
PIN 7 - activates Trigger Script 4 
 
 
 
PIN 8 - activates Trigger Script 7 
 
 
 
PIN 9 - activates Trigger Script 5 
Each pin that is to be used must first be programmed with a trigger script for the desired Go High and Go 
Low logic. To execute the Go Low script, a trigger input pin is connected via a sustained contact closure to 
pin 5 (ground). To execute a Go High script, the ground is removed from that pin. Each of the trigger pins 
(1, 2, 3, 4, 6, 7, 8, 9) is thus connected through a switch or relay to the Omnia-6’s ground on Pin 5. 
Let's review what we created for the example we showed you under "Using the Script Editor". Whenever 
pin 1 is held low (the contact or switch is in a closed state), the Omnia-6fm will switch to and stay in mono 
mode (no Pilot and only the left input channel is used). When the pin 1 contact is subsequently opened, the 
Omnia-6fm will switch back to and stay in stereo operation (pilot on and both left and right input channels 
being used) as long as the contact is open. 
"One Way Script" Functions 
You may also create scripting functions that do NOT return to another value when the remote contacts are 
opened. To do this, you use the Go LOW script only, and do not put any entries into the Go HIGH script. 
Two possible uses for this very useful "Go LOW Only" Trigger Script trick are periodically setting the 
Omnia's system time to an external standard, and remote re-booting of the Omnia. 
To use the Omnia's command line "Time" function to reset the Omnia's System Clock to midnight based on 
an external contact closure (such as from an automation system or other time reference), the script syntax 
would be: 
Time 00 00 00   Sets the Omnia time to midnight. Note that colons are not used as delimiters in this entry! 
Although time is displayed by the front panel display and its controller, it is actually being kept by the 
Omnia motherboard. When resetting the System Time using trigger scripts, the change takes effect 
immediately. However, because the front panel 'fetches' time synchronization from the motherboard every