Installation & Connections 
Throughout this section reference is made to “software parameters.” These are part of the Graphical User Interface, 
which is covered in detail in Chapter 2.  
Rack Mounting 
The Omnia-6fm requires 3RU (5.25" [37 mm]) of rack space. Rack mount the unit using four rack screws. If only 
two screws are going to be used, they should be in the bottom holes in the Omnia front panel. No other two-screw 
mounting arrangement will prevent distortion of the front panel casting! Adequate ventilation should be provided, 
and it is always good engineering practice to allow one blank rack space immediately above and below the Omnia, 
especially if equipment generating significant heat is located below the unit. Install a 1RU (1.75") vented or solid 
panel to fill these spaces.  
 
The processor should be installed into a thoroughly grounded 19" equipment rack.  Refer to Chapter 4, Omnia-6fm 
User Tips”, for additional considerations on where to physically locate your processor. 
AC Connection (IEC) 
The Omnia-6fm utilizes a heavily filtered, universal AC power-entry module. Its integral power switch is located just 
above the IEC power cord receptacle. The Omnia6-fm's voltage–sensing, switching power supply allows it to operate 
on AC mains voltages from 100 to 240 VAC, 50/60 Hz. In the USA, plug the provided IEC type AC power cord into 
the unit and then into a grounded AC outlet. Outside of the USA, you must use the appropriate power cord that 
complies with local electrical regulations. 
Press the “
I
” side of the rear-panel power switch to turn on the unit. The Omnia6-fm is designed to be continuously 
powered, however, pressing the “
O
” side of the switch turns off the unit for servicing.