312
System Setup, Auxiliary Area Allocations, and Built-in I/O Allocations
Appendix C
Sync Cycle Time
Sync Mode
Startup Mode Setting (CX-Programmer: Startup Tab Page)
Startup Mode
Cycle Time Settings (CX-Programmer: Timer/Peripheral Service)
Cycle Time
Watch Cycle Time
Address
Settings
Function
Related flags and 
words
When setting is 
read
Word
Bits
+319
00 to 14 0000 hex: Default (Coordina-
tor Module cycle time)
0001 to 0064 hex: 0.1 to 10.0 
ms (unit: 0.1 ms)
Default: Coordinator Module 
cycle time
Sets the cycle time for the Coordinator 
Module when high-speed synced oper-
ation is to be used only between Motion 
Control Modules. 
A404.06 (Sync Cycle 
Time Too Long Flag)
At power ON
Address
Settings
Function
Related flags and 
words
When setting is 
read
Word
Bits
+319
15
0: Sync mode
1: Async mode
Default: Sync mode
Sets either Sync Mode or Async Mode. 
Sync Mode is used to sync operation 
between the Coordinator Module and 
Motion Control Modules. 
Async Mode is convenient for debug-
ging Motion Control Modules even if 
Sync Mode is to be used for actual 
operation. 
---
At power ON
Address
Settings
Function
Related flags and 
words
When setting is 
read
Word
Bits
+81
00 to 11 00 hex: PROGRAM mode
01 hex: MONITOR mode
02 hex: RUN mode
Sets the mode in which the Coordinator 
Module will start. The mode set here 
can also be enabled and disabled. If 
this setting is disabled, the Coordinator 
Module will start in RUN mode.
---
At power ON
15
00: Setting disabled
01: Setting enabled
Default: Setting disabled
Address
Settings
Function
Related flags and 
words
When setting is 
read
Word
Bits
+307
00 to 15 0001 to 03E8 hex: 0.1 to 
100.0 ms (unit: 0.1 ms)
Default: 0000 hex (variable 
cycle time)
Set to 0001 to 03E8 hex to specify a 
constant (minimum) cycle time. If the 
cycle time is less than this setting, it will 
be extended until this time passes. 
Leave this setting at 0000 for a variable 
cycle time.
A404.05 (Constant 
Cycle Time Exceeded 
Flag)
At start of opera-
tion (cannot be 
changed during 
operation)
Address
Settings
Function
Related flags and 
words
When setting is 
read
Word
Bits
+308
00 to 15 0001 to 0064 hex: 1 to 100 
ms (unit: 0.1 ms)
Default: 0000 hex (50 ms)
Change this setting only when you want 
to change the default maximum cycle 
time. The Cycle Time Too Long Flag 
(A401.08) will be turned ON if the 
actual cycle time exceeds this setting.
A208 to A209 (Present 
Cycle Time)
At start of opera-
tion (cannot be 
changed during 
operation)