Omron V400-H111 Manual Do Utilizador

Página de 93
7
V400-H111/211
User’s Manual
In
trodu
ct
io
n
How 
to
 Us
e This Ma
nual
Introduction
How to Use This Manual
Page Format
Sec
tio
n
 4
Uploading from the Memory Card
Section 4
System Settings
69
V400-H111/211
User’s Manual
Communication Settings
The settings shown in the following table are set in the Communication Settings Tab
Page in the Create Setting Data Window.
The default settings are indicated with an asterisk.
Setting item
Settings
Baud Rate
9,600
*
, 19,200, or 38,400
Parity
None
*
, odd, or even
Data Length
77 bits or 
8 bits
*
Stop Bit
1sbit
*
 or 2 bits
Header/Footer
Prefix
None*
, 02 <STX>, or 1B <ESC>
Suffix
ETX, 0A LF, 
0D CR
*
, or 0D0A CR+LF
FCS
ON or 
OFF
*
65
V400-H111/211
User’s Manual
Sec
tio
n
 4
Cr
e
a
ting S
e
tt
ing File
s Us
ing t
h
e
 2DCR
 Conf
ige
ar
Section 4
System Settings
Creating Setting Files Using the 2DCR Configear  
Creates the data setting file for loading set data to the Handheld 2D Code Reader.
Make the settings for the communications conditions, functions, and display conversion.
Se
 lect Setting Reader - Create Data... from the menu.
The following window for creating the setting data file will be displayed.
■ Open
Opens the previously created data setting file for editing.
The [Receive (R)] function can be used to open the data file downloaded from the Code
Reader and edit it.
■ Save
Saves the created data setting file.
To save data to the Memory Card, create a folder with the name SETTINGS, and save. If the data is
saved to a folder other than “SETTINGS”, it cannot be uploaded.
*This page does not actually exist in this manual.
Section title
Outline
Index label
Provides the section number
and subject matter. Can be
used to immediately open the
desired page.
Screen display
Procedure and additional explanations
Information useful during the operation and
reference pages are provided here with special
marks to indicate the kind of information being
Describes the settings.
Move to the setting screen.