Quadra-Fire CASTILE-CE-MBK 7068-112 Manual Do Utilizador

Página de 32
Page 14
August 19, 2011
Castile & Santa Fe CE Pellet Stove 
R
7068-112
Clean-Out Cover
12. Cleaning the Glass
•  Frequency:
When clear view of the firepot becomes
obscure
•  By: Homeowner
 a. Appliance must be completely cool before cleaning
glass.
 b.  Vacuum fly ash from glass and door rope.
 c. Use a damp paper towel or any non-abrasive glass
cleaner. Wipe off with dry towel.
11.  Soot and Fly Ash:  Formation & Need for Removal 
in Exhaust Venting System.
•  Frequency: Yearly or more frequently depending on
ash build-up.
•  By: Qualified Service Technician/Homeowner
Be  sure  the  appliance  is  allowed  to  cool,  has  been
unplugged and the exhaust blower is off.
The  products  of  combustion  will  contain  small  particles
of fly ash. The fly ash will collect in the exhaust venting
system and restrict the flow of the flue gases.
At start-up if there is incomplete combustion, or if there
is  a  shutdown  or  incorrect  operation  of  the  appliance  it
will lead to some soot formation. This will collect in the
exhaust venting system.
The venting (chimney) system may need to be cleaned at
least once a year or more often depending upon the qual-
ity of your fuel or if there is a lot of horizontal pipe sections.
Ash will build up more quickly in the horizontal sections.
13. Cleaning Exhaust Blower - Requires No Lubrication
•  Frequency:
Yearly or as needed
•  By: Qualified Service Technician
•  Task:  Contact your local dealer
14. Cleaning Convection  Blower - Requires No 
Lubrication
•  Frequency: Yearly or every 25 bags or more fre
quently depending on operating environ-
ment
•  By: Qualified Service Technician
•  Task:  Contact your local dealer.
Figure 15.1
15.  Cleaning the Top Vent Adapter
a.  The appliance must be in complete shutdown and the
exhaust blower should be off. Allow the appliance to
completely cool down.
b.  Open the clean out cover.
 Figure 15.1.
c.  Sweep out any ash build-up.
NOTE: Hearth & Home Technologies recommends to 
use a heavy duty vacuum cleaner specifically 
designed for solid fuel appliance cleaning.
16. Preparing Firebox for Non-Burn Season
•  Frequency:
Yearly at the end of the heating season
•  By: Homeowner
 a. Be  sure  the  appliance  is  allowed  to  cool,  has  been
unplugged and the exhaust blower is off.
 b. Remove all ash from the firebox and vacuum thoroughly.
 c.  Paint all exposed steel, including cast-iron.
•  Use the Touch-Up paint supplied with the appliance;
or;
•  Purchase paint from your local dealer.
•  Must use a high-temperature paint made specifi-
cially for heating appliances.
Handle glass assembly with care.
When cleaning glass:
•  Avoid striking, scratching or
slamming glass.
•  Do NOT clean glass when hot.
CAUTION
•  Do NOT use abrasive cleaners.
•  Refer to maintenance instructions.
Handle glass with care.
•  Inspect the gasket to ensure it is
undamaged.
•  Do NOT strike, slam or scratch glass.
•  Do NOT operate appliance with glass
assembly removed.
WARNING
•  Do NOT operate with glass cracked, broken or
scratched.
Clean-Out Cover