Nordyne Single Package Heat Pump R-410A Manual Do Utilizador

Página de 20
4
At the beginning of the defrost cycle, both the 
outdoor condenser fan and compressor will 
turn off. After approximately 30 seconds, the 
compressor will turn on and begin to heat the 
outdoor coil causing the ice and snow to melt. 
NOTE: While the ice and snow is melting, some 
steam may rise from the outdoor unit as the warm 
coil causes the melting frost to evaporate. When 
defrost is completed, the outdoor fan motor will 
start, and the compressor will turn off again. In 
approximately 30 seconds the compressor will 
start up again and continue normal operation.
System Shutdown
Change the thermostat’s system mode to OFF 
and the fan mode to AUTO (See Figure 1). 
NOTE: The system will not operate, regardless 
of the temperature selector setting.
Warranty Information
A warranty certificate with full details is 
included with the heat pump. Carefully review 
these responsibilities with your dealer or 
service company. The manufacturer will not be 
responsible for any costs found necessary to 
correct problems due to improper setup, improper 
installation, adjustments, improper operating 
procedure on the part of the user, etc. Some 
specifi c examples of service calls which are not 
included in the limited warranty are:
1. Correcting wiring problems in the electrical 
circuit supplying the heat pump.
2.  Resetting circuit breakers or other switches.
3.  Adjusting or calibrating of thermostat.
INSTALLER INFORMATION
General Information
The installer should comply with all local 
codes and regulations which govern the 
installation of this type of equipment. Local 
codes and regulations take precedence over 
any recommendations contained in these 
instructions. Consult local building codes and 
the National Electrical Code (ANSI CI) for special 
installation requirements. Read the following 
instructions completely before performing 
the installation.
Some states require installation and service 
personnel to be licensed. Unqualifi ed individuals 
should not attempt to interpret these 
instructions or install this equipment.
This equipment contains R-410A refrigerant 
under high pressure. Installation or servicing 
should only be performed by qualifi ed trained 
personnel thoroughly familiar with this type 
equipment and related system components.
 CAUTION:
This unit uses refrigerant R-410A. DO NOT 
under any circumstances use any other 
refrigerant in this unit. Use of another 
refrigerant will damage the unit.
Single packaged heat pumps are ready for easy 
and immediate installation and can be readily 
connected into the high static duct system of a 
home. This unit is completely assembled, wired, 
and run tested at the factory. This heat pump 
is designed for outdoor installation only. 
The 
only connections needed for installation are the 
supply and return ducts, the line voltage, and 
thermostat wiring. A complete heat pump system 
typically consists of:
•  Single Package Heat Pump
•  Home Fittings Kit
•  Unit Fittings Kit
• 2-Stage 
Cooling/Heating 
Thermostat
Use of components other than those specifi ed 
may invalidate ARI Certifi cation, Code Agency 
Listing, and limited warranty on the air 
conditioner.
Pre-Installation Check
Before you install this unit, the cooling load of 
the area to be conditioned must be calculated 
and a system of the proper capacity selected. It 
is recommended that the area to be conditioned 
be completely insulated and vapor sealed.
The electrical supply should be checked to 
determine if adequate power is available. If there 
is any question concerning the power supply, 
contact the local power company. 
 CAUTION:
To prevent personal injury and/or 
equipment damage, check thermostat 
manufacturer’s operation of fan relay 
circuit when in EMER HEAT. When 
the thermostat system mode is in the 
EMER HEAT position, the thermostat 
must energize the fan relay when the 
fan mode is in the AUTO position. 
Inspecting Equipment:
All units are securely packed at the time of 
shipment and, upon arrival, should be carefully 
inspected for damage. Claims for damage 
(apparent or concealed) should be filed 
immediately with the carrier.