Display the next statement number by typing I1 over the first two
positions of the line containing statement 0004.00 and pressing Enter.
When the new statement line is displayed, press F4 to display a prompt in
which to enter the input specification.
12. 
The field statement number 0005.00 screen appears. Here you will
define the third field in the SAMPLE file. Enter the data exactly as
shown in the data area prompt at the bottom of screen, as shown in Figure
D-7, and then press ENTER.
Figure D-7 SEU Edit screen for line 0005.00
Columns . . . :    1  80                                       Edit
QGPL/QRPGSRC 
 SEU==>
SAMPLE 
 FMT F  .....FFilenameIPEAF....RlenLK1AIOvKlocEDevice+......KExit++Entry+A....U1........                   
        *************** Beginning of data **********************************************   
0001.00      FSAMPLE  IP  F     128            DISK 
0002.00      ISAMPLE  NS 
0003.00      I                                        1  17 NAME
0004.00      I                                       18  52 TITLE 
0005.00 
        ****************** End of data *************************************************   
                                                                                                           
                                                                                                           
                                                                                                           
                                                                                                           
                                                                                                           
                                                                                                           
                          Prompt type . . .   **      Sequence number . . .  0005.00                       
                                                                                                           
                          Data area                                                                        
                          ....+... 1 ...+... 2 ...+... 3 ...+... 4 ...+... 5 ...+... 6.                    
                               I                                       53  602SALARY                       
                                                                                                           
                                                                                                           
                                                                                                           
 F3=Exit   F4=Prompt   F5=Refresh          F11=Previous record                                             
 F12=Cancel            F23=Select prompt   F24=More keys                                                   
Column 6 is the Form Type and must contain the letter I, which designates
this record as an input specification.
Use columns 44 through 47 to enter the beginning position of the Salary
field. This field starts at position 53.