Never use wood or plastic, it may break and block the parts.
  
 
  
Never spray any cleaning product on the emitter grid or burner area.  
  
6. Troubleshooting 
 
Problem 
Possible Cause 
 
What to do 
 
Air in gas line 
Purge  gas  line  by  holding 
control 
knob 
at 
“PILOT” 
position  for  at  least  two 
minutes. 
Blockage in orifice 
Clean orifice 
Gas pressure is low  
Replace cylinder 
Burner won’t light 
Igniter is not sparking 
Use  match  to  light  pilot 
through the hole at the base of 
heater head. 
Thermocouple  is  not  operating 
properly 
Replace thermocouple 
Dirt build up around pilot orifice 
Clean pilot orifice 
There may be a leak in the system 
that  has  been  detected  by  the 
safety system in the regulator. 
Check  connections  at  hose  to 
fuel line and fuel line to heater 
head.    Be  sure  Regulator 
hand  wheel  is  tightened  to 
cylinder valve properly. 
Pilot won’t stay lit 
 
High  wind  condition  blowing  out 
pilot flame 
Put  heater  in  more  protected 
location. 
Do  not  use  heater  in  winds: 
greater  than  10  miles/hr.  or 
temperature: below 40 F. 
Heater not leveled 
Level the heater 
The burner tilted 
Straighten burner 
Gas pressure is low 
Replace cylinder 
Emitter glows uneven 
Outdoor  temperature  is  below  40 
degrees  Fahrenheit  and  cylinder  is 
less than 20% full 
 
Refill  the  cylinder.  Using  full 
one.  
Stop  using  this  heater  when 
the temperature is below 40 F. 
The burner burn off oily materials 
During the first few minutes of 
the initial burning 
Burner emits smoke 
 
Blockage in burner 
Remove  blockage  and  clean 
burner inside & outside 
The base is not on a level surface 
Place  heater  on  a  level 
surface 
Dirt or film on dome and emitter 
Clean dome and emitter 
Carbon build up 
Blockage in burner 
Remove  blockage  and  clean 
burner and clean burner inside 
& outside.