Web Management Tree of Menus 
 
General Configuration  
 
Authentication: Enables/Disables Authentication (Login Prompt) for command line configuration/management via Serial and Ethernet 
Default: enable  
 
BootMessage: Enables/Disables the display of boot-messages during module boot-up 
Default: enable  
 
Autodialout: Enables/Disables Telnet Auto-Dialout authentication 
Default: enable  
 
Watch Dog: Enables/Disables the watchdog timer (6.5 seconds by default) 
Default: enable  
 
User Configuration  
 
Provides to add/delete/modify username and password to the group 
Notes:  
o
 
Default Groups: admin, users  
o
 
Default Users: admin, ipmodule  
o
 
Only Admin can configure the SocketEthernet IP  
 
Port Configuration 
 
Baud Rate :Sets the serial Baud Rate 
Default: 115200  
 
Buffer Size: Sets data buffer size to be sent from serial-to-ethernet. 
Default: 0  
 
Buffer Time: Sets the buffer time (t deci-secs) to wait before sending from serial-to-ethernet. If t=0, buffer-size=0 no delay. If t=0, buffer-size!=0 buffered 
till the buffer-size. If t!=0, buffer-size=0, no delay. If t!=0, buffer-size!=0 buffered till the buffer-size or Wait till t deci-sec whichever occurs first. 
Default: 0 deci-seconds  
 
Flow Control: Sets the Flow Control of the serial port 
Default value: rts-cts  
 
Parity: Sets the serial Parity 
Default value: none  
 
Data Bits: Sets the serial Data bits 
Default value: 8  
 
Stop Bits: Sets the serial Stop bits 
Default value: 1  
 
Escaes.multiTech.socketProduct.seipInfo.seipIPSetup.seipIPServiceSetup.seipe Monitor: Enables/Disables ‘‘monitor’’ flag to scan escape sequence 
and switch to command mode during Manual dialin (telnet) session 
Default: enable  
 
Escape String: Sets the escape string to be scanned during Manual Dialin session to switch to command mode 
Default: +++inet  
 
Connect Type: Sets the connect type of the serial port to Direct/Modem 
Default: Direct  
 
Connect State: Sets the connect state of the serial port to dialing/answering 
Default: Dialing  
 
Trig Mode: Sets the trigger mode on the serial port. This mode controls starting/stopping of the Serial Configuration session and Auto-Dialin Session 
Modes Description  
o
 
char 
Initiate a session (Configuration/Telnet/Udp), only on a reception of a character on the serial port s0 
o
 
dtr 
Initiate a session (Configuration/Telnet/Udp), only on seeing a DTR signal on the serial port s0 
o
 
dtr-char 
Initiate a session (Configuration/Telnet/Udp), either on reception of a character (OR) seeing the DTR signal on the serial port s0 
o
 
none 
Initiate a session (Configuration/Telnet/Udp), on module boot-up  
Default: dtr-char  
 
Login String: Sets the login string. When the trig mode is set to char/dtr-char and DTR is down, the session is initiated only if the configured login string is 
entered 
Default: NULL  
 
Echo Command: Enables/Disables the command echoing on the serial port 
Default: enable  
 
Telnet messages: Enables/Disables the Telnet Client (Manual and Auto-Dialin) connect messages on the serial port 
Default: disable  
 
(continued…)
 
 
Dialout monitor: Sets the dialout monitor to dtr/none 
Description