N-Tron 102PC-SE Manual Do Utilizador

Página de 40
12/1/2006 
27 
Scenario 1 – Manual Dialout 
 
 
Connect to the 102PC-SE using a telnet Client on port 23 (or configuration port). 
 
At the command prompt, invoke # dialout serial s0. Once the session is opened successfully, there can 
be two-way traffic between the telnet client and the serial device. 
o
 
You can switch from Command Prompt to Dialout session using "restore session" command. 
o
 
You can switch from Dialout session to Command Prompt using "<escape-monitor-string>" respectively. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Manual Dialout Feature through Command Shell
 
 
Commands to Setup Manual Dial-out with the 102PC-SE 
# set ip eth0 dhcp-client disable 
# set ip eth0 ip-address 192.168.2.1 
# set serial s0 baud-rate 115200 
# set serial s0 data-bits 8 
# set serial s0 parity none 
# set serial s0 stop-bits 1 
# set serial s0 flow-control rts-cts 
# save 
 
Once the above configuration is saved in the 102PC-SE, use a telnet client and connect to 192.168.1.202 on port 23. 
 
On successful login, at the 102PC-SE command prompt, invoke 
# dialout serial s0 
 
The serial port now opens for use. 
 
Notes: 
1. 
Only one dial-out session can be open at a time. 
2. 
The Dial-out session is closed when the Telnet session is closed, thereby releasing the serial port. 
3. 
When Dial-out session authentication is enabled as specified in Optional commands, the session prompts for user-name and 
password before opening the session successfully. (Enabled by default). 
4. 
The serial port is opened with the current serial configuration. 
5. 
When escape-monitor is enabled, care should be taken during file transfer that the escapemonitor-string is not part of the data. 
6.
 Manual dial-out is supported for the Telnet protocol ONLY and not for the UDP protocol.