N-Tron 102PC-SE Manual Do Utilizador

Página de 40
12/1/2006 
32 
Scenario 1 – Manual Serial Dial-in 
 
Login in to the Command prompt from the serial side. 
 
Invoke # telnet <ip-address> <port> at the command prompt. Once the session is opened successfully, there can be two-way traffic 
between the serial device and the remote server. 
 
You can switch from Command Prompt to Dial-in session using restore session command. 
 
You can switch from Dial-in session to Command Prompt using <escape-monitor-string>
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Manual Dial-in Feature Through the Command Shell 
 
 
Commands to Setup Manual Dial-In with the 102PC-SE 
# set ip eth0 dhcp-client disable 
# set ip eth0 ip-address 192.168.2.1 
# set serial s0 baud-rate 115200 
# set serial s0 data-bits 8 
# set serial s0 parity none 
# set serial s0 stop-bits 1 
# set serial s0 flow-control rts-cts 
# save 
 
Once the above configuration is saved on the 102PC-SE, login to the 102PC-SE through the serial port. At the command shell invoke: 
 
# telnet 192.168.2.10 23 
 
The telnet client on board in the 102PC-SE establishes a virtual serial tunnel between the serial device and the Telnet Server. 
 
Notes: 
1. 
You can not open more than one dial-in session. 
2. 
The dial-in session is closed when the telnet session is closed. 
3. 
When escape-monitor is enabled, care should be taken during file transfer that the escapemonitor- 
  ring is not part of the data. 
4.
 The manual dial-in is supported for Telnet ONLY and not for UDP.