Scenario 4 – Serial Tunneling Mode 
 
This scenario shows a serial tunnel established between two serial devices (Serial Device-1, Serial Device-2) using two 102PC-SEs, 
which are geographically located apart. 
 
 
Serial Tunneling 
 
Commands for Module-1 
(Configure for Serial Auto Dial-in). 
# set ip eth0 dhcp-client disable 
# set ip eth0 ip-address 192.168.2.1 
set ip telnet raw-mode enable 
# set serial auto-dialin enable 
set serial s0 raw-dialin enable 
# set serial s0 auto-dialin enable 
# set serial s0 auto-dialin trig-mode none 
# set serial s0 auto-dialin-ipaddress 192.168.2.10 
# set serial s0 auto-dialin-port 23 
# set serial s0 auto-dialin-protocol telnet 
# set serial s0 baud-rate 115200 
# set serial s0 data-bits 8 
# set serial s0 parity none 
# set serial s0 stop-bits 1 
# set serial s0 flow-control rts-cts 
# save
 
Commands for Module-2 
(Configure for Telnet Auto Dial-out) 
 
# set ip eth0 dhcp-client disable 
# set ip eth0 ip-address 192.168.2.10 
# set ip auto-dialout enable 
set ip telnet raw-mode enable 
# set serial s0 auto-dialout enable 
# set serial s0 auto-dialout-port 5000 
# set serial s0 auto-dialout-protocol telnet 
set serial s0 raw-dialout enable 
# set serial s0 baud-rate 115200 
# set serial s0 data-bits 8 
# set serial s0 parity none 
# set serial s0 stop-bits 1 
# set serial s0 flow-control rts-cts 