Klark Teknik U.S.A. Stereo Receiver DN530 Manual Do Utilizador

Página de 56
Chapter 4: Front Panel
DN530
14
Operator Manual
Gate section
The gate section houses six gate parameter control knobs, bypass and duck switches, 
and a set of six metering LEDs.  For more information on the gate controls and their 
uses, see Chapter 6 "Gate Control Functions" on page 19.
 
Item
Type
Label
Function
1
Control knob
ATTACK
Adjusts the time taken for the gate to open after an 
over-threshold signal.
2
Control knob
HOLD
Defines a waiting period before the gate starts to 
close once the signal has been detected as having 
fallen below threshold.
3
Control knob
RELEASE
Adjusts the time its takes for the gate to close after 
the program material falls back below threshold and 
the hold time has elapsed.
4
Control knob
ACCENT
Adds an overshoot characteristic when the gate is 
opening, which accentuates the transient.
5
Pushbutton
DUCK
Reverses the operation of the gate so that it closes 
when signals go over threshold and opens when they 
go below threshold.  When the DUCK switch is on, 
the ACCENT control and the ACC LED are disabled.
6
LED 
(orange)
Not applicable
On/off status indicator for the DUCK pushbutton.
7
Control knob
RANGE
Adjusts the amount of gain reduction that is applied 
to signals that are below threshold.
8
LED
Various
9
Control knob
THRESHOLD
Adjusts the operating point (threshold) of the gate.
10
Pushbutton
BYPASS
Disconnects the gate from the main signal path.
11
LED (red)
Not applicable
On/off status indicator for the BYPASS pushbutton.
3
2
4
5
6
7
8
9
10
11
1