Fan Modules
NetScreen-5000 Series 
5
F
AN
 M
ODULES
The NetScreen-5200 has a three-fan module and the NetScreen-5400 has a two-fan 
module. You can access the fan module from the left front side of each chassis.
To remove the NetScreen-5200 fan module, turn the fan knob in the unlock 
position, then gently pull the fan module lever toward you to slide the module 
out.
To remove the NetScreen-5400 fan module, loosen the two thumb screws that 
secure the fan module, then gently slide the module out.
If a fan stops operating due to failure or removal, then the system continues to run and 
generates an alarm. When you replace the fan, do not leave the fan tray empty for more 
than two minutes. See 
 for more information.
N
ET
S
CREEN
-5000 M
ODULES
The NetScreen-5000 Series systems support two module types:
NetScreen-5000 management modules
NetScreen-5000 Secure Port Modules (SPMs)
The following table shows the modules supported by each slot.
The following table shows the configurations for each Management Modules and Secure 
Port Module and shows if the firmware version is included on the Management Module or 
needs to be downloaded.
slot 1
slot 2
slot 3
slot 4
NetScreen-5200
Management 
Module
Secure Port 
Module
N/A
N/A
NetScreen-5400
Management 
Module
Secure Port 
Module
Secure Port 
Module
Secure Port 
Module
Configuration 1
Configuration 2
Configuration 3
Management Module
5000-MGT
5000-MGT2
5000-MGT2
Secure Port Module
5000-8G and/or 
5000-2G24FE
5000-8G and/or 
5000-2G24FE
5000-8G2 and/or 
5000-2XGE
Software Version
Software is installed on 
the shipping 
management module. 
Software is installed on 
the shipping 
management module
Must download from the 
support site. 
www.juniper.net/
support